Available from 25 kV to 800 kV for measurement, protection and control
Current Transformers, Inductive Voltage Transformers, Capacitive Voltage Transformers, Combined Current/Voltage Transformers and Station Service Voltage Transformers are designed to transform high current and high voltage levels down to low current and low voltage outputs in a known and accurate proportion specified by the product nameplate ratios. All units are tailored for specific applications, either to operate accurately at steady state conditions or to maintain reasonable accuracy reading up to extreme fault level conditions.
These products consist of high dielectric strength oil-filled designs using paper and foil shields impregnated with refined dehydrated and degassed transformer oil, or stress-controlled, shield-graded SF6 gas-insulated designs. This ensures conservative reliable performance for decades of service in demanding global outdoor environments.
Applications
WHY POLIPAR
POLIPAR is an innovator in instrument transformer technology and has the most comprehensive product line in the market. Access to the latest technology, global sourcing and up-to-date processes ensures long life and meets the most stringent needs defined by the industry. Some of the important benefits offered by POLIPAR supply are:
Flexible design enables customer-tailored solutions
IMB oil-minimum current transformers are based on a tank type (hairpin) design and available with porcelain or silicone rubber insulators.
IMB | ||
Installation | Outdoor | |
Design | Tank (Hairpin) type | |
Insulation | Oil-paper-quartz | |
Highest voltage for equipment | kV | 36 - 800 |
Max. primary current | A | Up to 4000 |
Short-circuit current | kA/1 sec | Up to 63 |
Insulators | Porcelain On request silicon rubber |
|
Creepage distance | mm/kV | ≥ 25 Longer on request |
Ambient temperature | ºC | -40 to +40 |
Design altitude | m | Maximum 1000 (Standard) Others on request |
Accuracy | Meets all IEC and IEEE metering and protection classes |
Gas-insulated instrument transformer for enhanced safety and reliability
TG Current transformer | |
Installation | Outdoor |
Design | Self-standing top-core type |
Insulation | SF6 gas |
Highest voltage for equipment | 72.5 - 800 kV |
Max primary current | Up to 4.000 A |
Short-circuit current | Up to 63 kA |
Insulators | Porcelain or composite |
Short time power frequency withstand voltage | Up to 975 kV |
SF6 leakage | Less than 0.1% for year |
Ambient temperature | -50 ºC to +40 ºC (Standard) |
Pollution level | IV (very heavy) |
Accuracy | Meets all IEC and IEEE metering and protection classes |